TECHNICAL DATA
Replace open pipe Ø (mm) |
12 |
Blowing force (N) |
22.5 |
Air consumption (Nm³/h) |
120 |
Sound level (dB(A)) |
96 |
Nozzle technology |
Multi laval |
Material (nozzle) |
1.4404 (316L) |
Connection |
G 1/2" |
Connection type |
Female |
Weight (kg) |
0.0470 |
Max temp (°C) |
400 |
Max op. pressure (MPa) |
1.0 |
Benefits when replacing an open pipe
Replace open pipe Ø (mm) |
12 |
|
Noise reduction |
20 [dB(A)] |
75% |
Energy savings |
146 [Nm³/h] |
55% |
Material specification: EN 1.4404
Blowing properties at different pressures
Pressure (kPa) | 200 | 400 | 600 | 800 | 1000 |
Blowing force (N) |
8.7 |
17.9 |
27.0 |
36.2 |
45.3 |
Air consumption (Nm³/h) |
64.0 |
101.0 |
142.0 |
180.0 |
219.0 |
Sound level (dB(A)) |
92.1 |
94.4 |
95.9 |
96.8 |
97.2 |
Blowing coverage
Blowing dist. (mm) | Blowing coverage (mm) |
50 |
40 |
100 |
80 |
200 |
120 |
300 |
160 |
400 |
200 |
500 |
240 |