TECHNICAL DATA
Replace open pipe Ø (mm) |
25 |
Blowing force (N) |
98.0 |
Air consumption (Nm³/h) |
636 |
Sound level (dB(A)) |
105 |
Nozzle technology |
Slot |
Material (nozzle) |
1.4305 (303) |
Connection |
G 1" |
Connection type |
Female |
Weight (kg) |
0.6960 |
Max temp (°C) |
400 |
Max op. pressure (MPa) |
1.0 |
Benefits when replacing an open pipe
Replace open pipe Ø (mm) |
25 |
|
Noise reduction |
26 [dB(A)] |
84% |
Energy savings |
523 [Nm³/h] |
45% |
Material specification: EN 1.4305
Blowing properties at different pressures
Pressure (kPa) | 200 | 400 | 600 | 800 | 1000 |
Blowing force (N) |
31.8 |
75.3 |
117.9 |
161.9 |
205.3 |
Air consumption (Nm³/h) |
275.6 |
518.5 |
750.0 |
990.6 |
1228.3 |
Sound level (dB(A)) |
97.3 |
102.5 |
106.3 |
107.7 |
109.1 |
Blowing coverage
Blowing dist. (mm) | Blowing coverage (mm) |
50 |
200 |
100 |
260 |
200 |
315 |
300 |
370 |
400 |
445 |
500 |
485 |